<LOGO>
FM Transmitter Measurement Report
Created: 2025-03-07 10-16-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
92.10 MHz 5/5, 66 dBuV MOUV'
Pilot RDS Phase Difference
6.6 kHz 3.7 kHz -82 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 71 kHz 10020 0,0100
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
6,6 dBr 7,62 dBr 8,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" MOUV' " F208 0 (No PTY) 1 0 1 1 10:16, 7.03.2025
RT
"DON'T MESS WITH MY MAN - LUCY PEARL (2000) - LA PLAYLIST "
AF EON
91.0, 92.1, 95.8, 101.1 MHz F201, F203, F222, F20A
FM Scope Station: 92.10 MHz, signal: 4/5 (68 dBuV) Max at: 71 kHz MIN: 10 kHz % above 75 kHz: 0,0100 Acquired: 2025/03/07 10:15:03 Total samples: 10020 Equivalent time: 0:08:21 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 8,4 dBr MIN: 6,6 dBr AVE: 7,62 dBr % above 10,0 dBr: 0,0 Last value: 7,6 dBr (2025/03/07 10:15:03) Station: 92.10 MHz, signal: 5/5 (67 dBuV) 10:08 10:09 10:10 10:11 10:12 10:13 10:14 10:15 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality